z-logo
open-access-imgOpen Access
Tank 241-AN-103, cores 166 and 167 analytical results for the final report
Author(s) -
F.H. Steen
Publication year - 1997
Language(s) - English
Resource type - Reports
DOI - 10.2172/350827
Subject(s) - sample (material) , environmental science , statistics , sample size determination , mathematics , waste management , engineering , chemistry , chromatography
This document is the analytical laboratory report for tank 241-AN-103 [Hydrogen Watch Listed] push mode core segments collected between September 13, 1996 and September 23, 1996. The segments were subsampled and analyzed in accordance with the Tank 241-AN-103 Push Mode Core Sampling and Analysis Plan (TSAP), the Safety Screening Data Quality Objective (DQO) and the Flammable Gas Data Quality Objective (DQO). The analytical results are included in the data summary table. The raw data are included in this document. None of the samples submitted for Total Alpha Activity (AT), Total Organic Carbon (TOC) and Plutonium analyses exceeded notification limits as stated in the TSAP. One sample submitted for Differential Scanning Calorimetry (DSC) analysis exceeded the notification limit of 480 Joules/g (dry weight basis) as stated in the Safety Screening DQO. Appropriate notifications were made. Statistical evaluation of results by calculating the 95% upper confidence limit is not performed by the 222-S Laboratory and is not considered in this report. Appearance and Sample Handling Attachment 1 is a cross reference to relate the tank farm identification numbers to the 222-S Laboratory LabCore/LIMS sample numbers. The subsamples generated in the laboratory for analyses are identified in these diagrams with their sources shown. The diagrams identifying the core composites are also included. Core 166 Nineteen push mode core segments were removed from tank 241-AN-103 riser 12A between September 13, 1996 and September 17, 1996. Segments were received by the 222-S Laboratory between September 20, 1996 and September 30, 1996. Table 2 summarizes the extrusion information. Selected segments (2, 5 and 14) were sampled using the Retained Gas Sampler (RGS) and extruded by the Process Chemistry and Statistical Analysis Group. Core 167 Eighteen push mode core segments were removed from tank 241-AN-103 riser 21A between September 18, 1996 and September 23, 1996. Tank Farm Operations were unsuccessful in obtaining segment 19 due to the high downforce encountered during sampling. Segments were received by the 222-S Laboratory between September 23, 1996 and September 30, 1996. Table 3 summarizes the extrusion information

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here