Subject(s) - freon , government (linguistics) , waste management , process (computing) , contamination , chlorinated solvents , environmental science , engineering , process engineering , construction engineering , computer science , chemistry , ecology , philosophy , linguistics , organic chemistry , biology , operating system
As of December 1995, the manufacture of Freon, along with many other chlorofluorocarbons (CFCs), was prohibited by the Clean Air Act of 1990 (CAA). The ban of CFC solvents has forced manufacturers across the country to search for alternative metal cleaning techniques. The objective of this study was to develop a thorough, scientific based approach for resolving one specific manufacturer`s problem of removing organic contamination from a stainless steel part. This objective was accomplished with an approach that involved: (1) defining the problem, (2) identifying the process constraints, (3) researching alternate cleaning methods, (4) researching applicable government regulations, (5) performing a scientific evaluation and (6) drawing conclusions