Flexible receiver adapter and secondary bagger support frame analysis for 241AP102 mixer pump removal
Author(s) -
M.D. Axup,
J. Egger
Publication year - 1995
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/273656
Subject(s) - adapter (computing) , frame (networking) , process (computing) , engineering , computer science , grout , structural engineering , mechanical engineering , electrical engineering , operating system
As part of the Grout Process startup, the 241AP102 Mixer Pump, failed in 1993, is scheduled to be removed. A structural analysis was performed on two components to be used in the bagging process for the failed pump. The loading criteria was based on a worst case accident of the entire pump weight (including a 50% impact load) being applied over a small localized area. The results show that the design of each structure is adequate to protect against failure, i.e., yiel