Neutron Exposure Parameters for the Dosimetry Capsule in the Heavy-Section Steel Irradiation Program Tenth Irradiation Series
Author(s) -
Charles A. Baldwin,
F.B.K. Kam,
Igor Remec
Publication year - 1998
Language(s) - English
Resource type - Reports
DOI - 10.2172/1300
Subject(s) - dosimetry , dosimeter , irradiation , neutron flux , fluence , neutron , radiochemistry , materials science , nuclear physics , physics , nuclear medicine , chemistry , medicine
This report describes the computational methodology for the least-squares adjustment of the dosimetry data from the HSSI 10.OD dosimetry capsule with neutronics calculations. It presents exposure rates at each dosimetry location for the neutron fluence greater than 1.0 MeV, fluence greater than 0.1 MeV, and displacements per atom. Exposure parameter distributions are also described in terms of three- dimensional fitting functions. When fitting functions are used it is suggested that an uncertainty of 6% (1 o) should be associated with the exposure rate values. The specific activity of each dosimeter at the end of irradiation is listed in the Appendix