Multi-Canister overpack sealing configuration
Author(s) -
K.E. SMITH
Publication year - 1998
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/11247
Subject(s) - closure (psychology) , schedule , engineering , seal (emblem) , shield , welding , mechanical engineering , forensic engineering , computer science , geology , petrology , art , economics , market economy , visual arts , operating system
The Spent Nuclear Fuel (SNF) position regarding the Multi-Canister Overpack (MCO) sealing configuration is to initially rely on an American Society of Mechanical Engineers (ASME) Section III Subsection NB code compliant mechanical closure/sealing system to quickly and safely establish and maintain full confinement of radioactive materials prior to and during MCO fuel drying activities. Previous studies have shown the mechanical seal to be the preferred closure method, based on dose, cost, and schedule considerations. The cost and schedule impacts of redesigning the mechanical closure to a welded shield plug do not support changing the closure system. The SNF Project has determined that the combined mechanical/welded closure system meets or exceeds the regulatory requirements to provide redundant seals while accommodating key safety and schedule limitations that are unique to K Basins fuel removal effort
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom