241-AZ Tank Farm Construction Extent of Condition Review for Tank Integrity
Author(s) -
Travis J. Barnes,
Kayle D. Boomer,
Jason R. Gunter
Publication year - 2013
Language(s) - English
Resource type - Reports
DOI - 10.2172/1089516
Subject(s) - storage tank , engineering , benchmark (surveying) , forensic engineering , environmental science , waste management , geography , cartography
This report provides the results of an extent of condition construction history review for tanks 241-AZ-101 and 241-AZ-102. The construction history of the 241-AZ tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AZ tank farm, the second DST farm constructed, both refractory quality and tank and liner fabrication were improved