Author(s) -
Linde
Publication year - 2011
Language(s) - English
Resource type - Reports
DOI - 10.2172/1034398
Subject(s) - heat exchanger , boiler (water heating) , mechanical engineering , test data , engineering drawing , engineering , nuclear engineering , computer science , waste management , software engineering
Based on the JLab study and calculations, Linde made the following changes to the LR1610 heat exchanger. The LR 1610 redesign changed two different aspects of the original LR1610 design. The heat exchanger and the boiler are wrapped differently than the original LR1610 per the following: (A) Heat Exchanger - Section A - Current LR 1610 - 2 wraps - 1 path, Redesign - 2 wraps - 2 paths; Section B: Current LR 1610 - 2 wraps - 1 path, Redesign - 2 wraps - 2 paths; (B) Boiler: Current design - 1 wrap - 2 paths, Redesign - 1 wrap - 1 path. The contents of the attachments are: (1) Assembly - Pictures of the LR1610 Redesign Heat Exchanger after manufacturing; (2) Drawings - 3D and 2D drawings used to fabricate the Redesign LR1610 Heat Exchanger and the Precooler-Boiler; (3) Performance Curves - The expected performance curves and the TS diagram for a single proposed new compressor that is more capacity than the RSX; (4) Test Pictures - Set up bench test of the LR1610 Redesign Heat Exchanger; and (5) Warm Test Data - Warm N2 test data of the LR1610 Redesign Heat Exchanger. Warm test data of the LR1610 Redesign Heat Exchange vs. the warm test data of the two standard LR1610 heat exchangers