D0 Solenoid Upgrade Project: Pressure Ratings for Some Chimney and Control Dewar Componenets
Author(s) -
R. Rucinski
Publication year - 1993
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/1031791
Subject(s) - chimney (locomotive) , upgrade , table (database) , control (management) , engineering , mechanical engineering , nuclear engineering , computer science , database , operating system , inlet , artificial intelligence
Pressure rating calculations were done for some of the chimney and control dewar components. This engineering note documents these calculations. The table below summarizes the components looked at, and what pressure rating are. The raw engineering calculations for each of the components is given
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom