z-logo
open-access-imgOpen Access
D0 Solenoid Upgrade Project: Heat Load Calculations for the Solenoid Chimney
Author(s) -
R. Rucinski
Publication year - 1993
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/1031788
Subject(s) - chimney (locomotive) , upgrade , heat load , solenoid , shield , mechanical engineering , nuclear engineering , environmental science , engineering , computer science , physics , thermodynamics , geology , operating system , petrology , inlet
This engineering note documents the calculations done to determine the chimney heat loads. These heat load numbers were reported in the D0 solenoid upgrade design report. The heat loads to the LN2 circuit were done by Andrew Stefanik, RDIMechanical Systems group. They were part of his LN2 shield calculations dated 2/23/93. Pages 1 thru 3 of his calculations that apply to the chimney are attached. The heat loads to the LHe circuit were done originally on 12/16/92 and then revised on 12/23/92 to be more conservative. The raw calculations are attached. I include both the original 12/16 version and the 12/23 revised version to document the amount of conservativeness added