Cold Mass Support System for he D0 Solenoid
Author(s) -
B. Squires
Publication year - 1993
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/1031776
Subject(s) - stiffness , structural engineering , tension (geology) , cryostat , solenoid , cushion , materials science , compression (physics) , engineering , mechanical engineering , physics , composite material , superconductivity , quantum mechanics
The support system is designed to support the gravitational, magnetic, and thermal contraction loads associated with the cold mass weighing 1.46 metric tons (3210 Ibm). The loading constraints are listed in Table 1. The support system consists of axial members (axial supports) to provide longitudinal stiffness and nearly tangential members (radial supports) to provide radial stiffness. The members connect the outer support cylinder to the flat annular bulkheads of the vacuum vessel. See Figures 1 through 3 for additional details on the supports. Six axial compression-tension supports are located on the chimney end of the cryostat only. Six radial tension supports are located on each end. Both types of members are fabricated of Inconel 718 and have a design safety factor of 4 on the ultimate strength at 300 K. The axial supports are also designed for a buckling safety factor of 4 for the operating loads. Shipping stops will be installed to prevent the axial supports from going into compression during transportation. Axial and radial contraction of the coil support cylinder is accommodated by spherical bearings on both ends ofeach support member

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom