Evaluation of gas-reburning and low NO{sub x} burners on a wall fired boiler. Progress report No. 18, January 1--March 31, 1995
Author(s) -
Colorado Springs Colorado Interstate Gas Co.
Publication year - 1995
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/102486
Subject(s) - boiler (water heating) , natural gas , coal , waste management , environmental science , sulfur , staged combustion , combustion , nuclear engineering , engineering , chemistry , materials science , metallurgy , combustion chamber , homogeneous charge compression ignition , organic chemistry
The primary objective of this project is to evaluate the use of Gas Reburning and Low NO{sub x} Burners (GR-LNB) for NO{sub x} emission control from a wall fired boiler. It is anticipated that, if the demonstration is successful, the GR-LNB technology could become commercialized during the 1990`s and will be capable of (1) achieving significant reduction in the emissions of nitrogen oxides and sulfur dioxide (another acid rain precursor) from existing facilities to minimize environmental impacts such as transboundary and interstate pollution and/or (2) providing for future energy needs in an environmentally acceptable manner. Low NO{sub x} burners are designed to delay the mixing of the coal fuel with combustion air to minimize the NO{sub x} formation. Typically, one may obtain up to 50% reduction in NO{sub x} emissions through the use of LNB. For LNB applications, the technology is developed and a number of LNB designs are commercially available. With GR, about 80--85 percent of the coal fuel is fired in the main combustion zone. The balance of the fuel is added downstream as natural gas to create a slightly fuel rich environment in which NO{sub x} is converted to N{sub 2}. The combustion process is completed by over-fire air addition. SO{sub x} emissions are reduced to the extent that natural gas replaces sulfur-containing coal. The level of NO{sub x} reduction achievable with 15--20% natural gas is on the order of 50--60%. Thus the emission reduction target of the combination of these two developed technologies is about 70%
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom