Cool-down and frozen start-up behavior of a grooved water heat pipe
Author(s) -
Jinhyuk Jang
Publication year - 1990
Language(s) - English
Resource type - Reports
DOI - 10.2172/10181001
Subject(s) - heat pipe , evaporator , condenser (optics) , micro loop heat pipe , materials science , working fluid , isothermal process , adiabatic process , mechanics , thermodynamics , heat transfer , heat exchanger , light source , physics , optics
A grooved water heat pipe was tested to study its characteristics during the cool-down and start-up periods. The water heat pipe was cooled down from the ambient temperature to below the freezing temperature of water. During the cool-down, isothermal conditions were maintained at the evaporator and adiabatic sections until the working fluid was frozen. When water was frozen along the entire heat pipe, the heat pipe was rendered inactive. The start-up of the heat pipe from this state was investigated under several different operating conditions. The results show the existence of large temperature gradients between the evaporator and the condenser, and the moving of the melting front of the working fluid along the heat pipe. Successful start-up was achieved for some test cases using partial gravity assist. The start-up behavior depended largely on the operating conditions.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom