A rapid technique to determine performance and efficiency of activated carbon water filters
Author(s) -
Martin J. Sweetman,
Damien A. Sebben,
Ben Noll,
Wei Hong Wang,
Steve May,
Nick Mebberson,
Sally E. Plush,
John D. Hayball
Publication year - 2017
Publication title -
water science and technology water supply
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.318
H-Index - 39
eISSN - 1607-0798
pISSN - 1606-9749
DOI - 10.2166/ws.2017.123
Subject(s) - dissolved organic carbon , activated carbon , fluorescence spectroscopy , chemistry , chlorine , fluorescence , carbon fibers , effluent , environmental chemistry , water treatment , spectroscopy , analytical chemistry (journal) , chromatography , environmental engineering , environmental science , materials science , organic chemistry , adsorption , physics , quantum mechanics , composite number , composite material
The performance of activated carbon water filters, with respect to the breakthrough of dissolved organic matter (DOM) and dangerous trihalomethanes (THMs) from supplied water, has been analysed by fluorescence spectroscopy. Fluorescence spectroscopy has been demonstrated as a viable technique to monitor carbon filter performance, using the fluorescently active DOM species as an indicator. Due to the relationship between DOM and THMs, where DOM is the precursor for THM formation during the chlorine treatment of water, fluorescence spectroscopy can be used to predict the breakthrough of both species from activated carbon filters. In order to establish a versatile measurement technique, the most appropriate fluorescence excitation and emission wavelengths for detecting the DOM in water were firstly determined. These fluorescence measurement parameters were then applied to effluent water samples from carbon filters, over a total filtrate volume of 4,200 L. The total THM concentration in filtered water samples was determined by headspace gas chromatography (HSGC), with the fluorescence and HSGC results showing a high degree of correlation for the amount of DOM and THM respectively. Importantly, this correlation is observed for both of the determined fluorescence measurement parameters, highlighting the validity and versatility of this technique.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom