Adaptive water distribution networks with dynamically reconfigurable topology
Author(s) -
R.W. Wright,
Ivan Stoianov,
Panos Parpas,
Kevin Henderson,
John R. King
Publication year - 2014
Publication title -
journal of hydroinformatics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.654
H-Index - 50
eISSN - 1465-1734
pISSN - 1464-7141
DOI - 10.2166/hydro.2014.086
Subject(s) - redundancy (engineering) , control reconfiguration , computer science , network topology , leakage (economics) , distributed computing , resilience (materials science) , topology (electrical circuits) , reliability engineering , engineering , embedded system , computer network , physics , electrical engineering , economics , macroeconomics , thermodynamics
This paper presents a novel concept of adaptive water distribution networks with dynamically reconfigurable topology for optimal pressure control, leakage management and improved system resilience. The implementation of District Meter Areas (DMAs) has greatly assisted water utilities in reducing leakage. DMAs segregate water networks into small areas, the flow in and out of each area is monitored and thresholds are derived from the minimum night flow to trigger the leak localization. A major drawback of the DMA approach is the reduced redundancy in network connectivity which has a severe impact on network resilience, incident management and water quality deterioration. The presented approach for adaptively reconfigurable networks integrates the benefits of DMAs for managing leakage with the advantages of large-scale looped networks for increased redundancy in connectivity, reliability and resilience. Self-powered multi-function network controllers are designed and integrated with novel telemetry tools for high-speed time-synchronized monitoring of the dynamic hydraulic conditions. A computationally efficient and robust optimization method based on sequential convex programming is developed and applied for the dynamic topology reconfiguration and pressure control of water distribution networks. An investigation is carried out using an operational network to evaluate the implementation and benefits of the proposed method.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom