Future directions for electrospray ionization for biological analysis using mass spectrometry
Author(s) -
Richard Smith
Publication year - 2006
Publication title -
biotechniques
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.617
H-Index - 131
eISSN - 1940-9818
pISSN - 0736-6205
DOI - 10.2144/000112217
Subject(s) - electrospray ionization , electrospray , national laboratory , mass spectrometry , chemistry , biomolecule , characterization (materials science) , ionization , analytical chemistry (journal) , chromatography , nanotechnology , physics , engineering physics , materials science , ion , organic chemistry , biochemistry
When John Fenn and coworkers first realized Malcolm Dole’s dream of electrospray ionization (ESI) (1), the broad impact it would ultimately have was not obvious to most researchers working in the (admittedly much smaller) field at the time (2). Indeed, between his first publication in 1984 and ground breaking report in 1988 that described ESI-mass spectrometry (ESI-MS) as a tool for analyzing large proteins (3), my laboratory was one of the very few (and perhaps the only?) working with ESI-MS (4). After Fenn’s 1988 seminal publication, the MS community broadly recognized the potential of ESI-MS for providing the long sought effective interface between liquid chromatography (LC) separations and MS that would allow a large range of previously intractable biomolecules to be studied.Over the last 20+ years, the range and types of ESI-MS applications has expanded in a breathtaking fashion to include essentially every class of biomolecules and, for example, the characterization of extremely large noncovalently associated protein complexes. As a result of its sensitivity, now broad availability, and applicability, ESI-MS has become a dominant analytical tool for areas of biological research such as proteomics, which is the study of the array of proteins in an organism, tissue, or cell at a given time. Its ability to broadly measure biological macromolecules, especially proteins, can play an important role in delineating complex cellular networks and pathways, as well as in a range of other applications, such as candidate biomarker discovery efforts.In this context it is fair to ask, what’s next? Will ESI be displaced by some other method of ionization or LC-MS interfacing? Are there important new developments still to come? Of course, the possibility of completely new approaches—“disruptive” new technologies that revolutionize how we work—should never be excluded. By their nature, one cannot predict such develop-ments, but we can more reasonably speculate on, and more reliably predict, the impact of more evolutionary developments that arise from the naturally selective process of on-going focused efforts. I believe that such forces, involving ESI driven by the need for more sensitive and better quantitative measurements, are now at play in ways that will greatly expand its utility for biological applications.The need for greater sensitivity to better detect, identify, and quantify biomolecules in proteomics is essentially open-ended; every improvement enables new applications. For example, the ability to make comprehensive proteomic measurements generally depends on the sample size, as well as on both the sensitivity and dynamic range of measurements. Improvements in measurement sensitivity can enable different approaches (e.g., for characterizing microdissected cells, microbiopsies, or even single cells), while extensions to the range of measurable protein abundances can facilitate identification of disease specific biomarkers (e.g., from blood) and provide the basis for new clinical assays. However, it is often necessary to resort to a “divide and conquer” sample fractionation strategy to obtain sufficient depth of proteome coverage (i.e., measurement dynamic range). Indeed, the real limitations to achieving sufficient depth with present proteome measurements are essentially derived from considerations associated with the amount of sample available and the sensitivity of the measurements methods. When the sample size is very small, and fractionation steps, etc., must be either minimized or eliminated to conserve the sample, measurement sensitivity becomes the limiting factor.The overall sensitivity of ESI-MS is limited by factors that include both ionization efficiency and ion transmission efficiency into and through the MS analyzer. At the liquid flow rates of conventional LC separations, ESI-MS response typically appears concentration-sensitive rather than mass-sensitive; that is, increasing the flow rate does not greatly increase the signal (5). However, as flow rates are lowered, the smaller charged droplets generated by an electrospray result in increased ionization efficiency (i.e., transfer of an ion from solution to the gas phase) and also permit the ESI emitter to be positioned closer to the MS inlet to allow more efficient transport to the MS analyzer, both of which provide increased sensitivity (6,7). For example, ESI-MS analyses that used flow rates of approximately 20 nL/min demonstrated significantly increased sensitivity (8) compared with flow rates typically applied with LC separations (7). The overall predicted efficiency for converting analyte ions from solution to gas phase approaches 100% when both the liquid flow rate and analyte concentration are sufficiently low (9). Additionally, smaller inner diameter (i.d.) columns with lower flow rates provide higher sensitivity than larger i.d. columns with higher flow rates (10). As ionization efficiencies are increased to produce nano-electrosprays, detection biases are also decreased since undesired matrix effects and/or ionization suppression effects are either reduced or eliminated, which can significantly improve quantitation. The use of 10 μm i.d. silica-based monolithic LC columns (11) providing flow rates on the order of 10 nL/min (i.e., nano-flow) has been shown to both increase sensitivity and improve quantitation.Comparisons of the relative abundances of different proteins, and quantitative approaches in general, are improved by minimizing variations in ESI response. An advantage of low flow rate separations is that compound-to-compound variations in MS response are minimized, thus providing an improved basis for label-free quantitative measurements. In label-free analyses, LC-MS peak intensities for the same species are compared among different analyses (12), often following normalization to attempt to account for variations in sample quantity and/or instrument performance between analyses. These types of analyses are very sensitive to differences in ionization efficiencies between different species, ionization suppression, matrix effects in
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom