z-logo
open-access-imgOpen Access
Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS): Comparison of Different Internal Standardization Methods Using Laser-induced Plasma (LIP) Emission and LA-ICP-MS Signals
Author(s) -
Masaki Ohata,
Hiroyuki Yasuda,
Yoshimichi Namai,
Naoki Furuta
Publication year - 2002
Publication title -
analytical sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.392
H-Index - 73
eISSN - 1348-2246
pISSN - 0910-6340
DOI - 10.2116/analsci.18.1105
Subject(s) - chemistry , inductively coupled plasma mass spectrometry , analytical chemistry (journal) , mass spectrometry , laser , laser ablation , inductively coupled plasma , certified reference materials , detection limit , plasma , chromatography , optics , physics , quantum mechanics
The source of signal variations that governs the analytical performance of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was investigated in this study. In order to specify the source of signal variations of LA-ICP-MS, laser-induced plasma (LIP) Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards for the determination of trace elements in low-alloy steel certified reference materials (BS 50D and JSS 1005-1008). Fe 1373.5 nm emission signals from LIP were measured, while trace element LA-ICP-MS signals were collected. After that, the LIP emission signals, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards, and the analytical performance was evaluated by the RSDs and the correlation coefficients (r) of the calibration curves. The improvement factors were dependent on the internal standardization methods. Analytical precisions (RSDs) of trace element LA-ICP-MS signals were improved by factors of 1.5-3.3 using LIP Fe emission signals as an internal standard. The improvement factors of 2.5 - 5.9 and 4.1 - 17 were obtained by using LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals as internal standards, respectively. Better correlation coefficients (r) were also obtained using the LA-ICP-MS signal compensation (0.9985 by LA-ICP-MS Fe+ and 0.9996 by LA-ICP-MS Ni+) rather than the LIP Fe emission compensation (0.9932). In this paper we compare and discuss the analytical performance achieved by LA-ICP-MS using LIP Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals as internal standards.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom