z-logo
open-access-imgOpen Access
Prototype Sistem Deteksi Partial Discharge Pada Isolasi Kabel Menggunakan Sensor Microphone
Author(s) -
Mochamad Zaeynuri Setiawan,
Fachrudin Hunaini,
Mohamad Mukhsim
Publication year - 2019
Publication title -
jeee-u (journal of electrical and electronic engineering-umsida)
Language(s) - English
Resource type - Journals
eISSN - 2540-8658
pISSN - 2460-9250
DOI - 10.21070/jeee-u.v3i2.2450
Subject(s) - partial discharge , microphone , electrical engineering , microcontroller , measure (data warehouse) , acoustics , engineering , computer hardware , computer science , physics , voltage , loudspeaker , database
The phenomenon that often arises in a substation is the problem of partial discharge in  outgoing cable insulation. Partial discharge is a jump of positive and negative ions that are  not supposed to meet so that it can cause a spark jump. If a partial discharge is left too long  it can cause insulation failure, the sound of snakes like hissing and the most can cause a flashover on the outgoing cable. Then a partial discharge detection prototype was made in the  cable insulation in order to anticipate the isolation interference in the outgoing cable. Can  simplify the work of substation operators to check the reliability of insulation on the outgoing  side of each cubicle. So it was compiled as a method for measuring sound waves caused by  partial discharge in the process of measuring using a microphone sensor, the Arduino Mega  2560 module as a microcontroller, the LCD TFT as a monitoring and the MicroSD card module as its storage. The microphone sensor is a sensor that has a high sensitivity to sound, has 2 analog and digital readings, and is easily designed with a microcontroller. Basically the unit of measure measured at partial discharge is Decibels. The results of the prototype can be  applied to the cubicle and the way it works is to match the prototype to the outgoing cubicle  cable then measure from the cable boots connector to the bottom of the outgoing cable with  a distance of 1 meter. Then the measurement results will be monitored on the TFT LCD  screen in the form of measurement results, graphs and categories on partial discharge. In  this design the measurement data made by the microphone can be stored with microSD so that it can make an evaluation of partial discharge handling in outgoing cable insulation.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom