Successful percutaneous treatment with the Konar MFTM-VSD Occluder in an infant with Abernethy syndrome—case report
Author(s) -
Petra Loureiro,
Stanimir Georgiev,
Peter Ewert,
Daniel Tanase,
Andreas Eicken,
Birgit Kammer,
Robert DallaPozza
Publication year - 2021
Publication title -
cardiovascular diagnosis and therapy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 22
eISSN - 2223-3660
pISSN - 2223-3652
DOI - 10.21037/cdt-20-380
Subject(s) - medicine , percutaneous , pediatrics , surgery
Cyanosis persisting after surgical repair of complex congenital heart disease (CHD) may be related to the underlying disease. However, extracardiac causes should be also considered. We report on a patient with heterotaxy syndrome and double outlet right ventricle, in whom postoperative cyanosis was associated with an Abernethy malformation type II causing a hepatopulmonary syndrome. Despite this complex anatomy, interventional closure of the portosystemic shunt was done with a Konar MF™-VSD Occluder. The patient recovered rapidly with relief of cyanosis within one month. This case highlights the importance of a careful diagnostic assessment in patients with complex CHD, who presents cyanoses after surgical repair. In addition, it shows the feasibility and safety of a percutaneous approach with complete closure of the vascular malformation in a patient with a complex anatomy.