Potentiometric determination of cysteine with thiol sensitive silver-mercury electrode.
Author(s) -
Ryszard Drożdż,
J Naskalski,
Anna Ząbek-Adamska
Publication year - 2007
Publication title -
acta biochimica polonica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.452
H-Index - 78
eISSN - 1734-154X
pISSN - 0001-527X
DOI - 10.18388/abp.2007_3288
Subject(s) - cysteine , chemistry , thiol , dropping mercury electrode , reference electrode , inorganic chemistry , electrode , potentiometric titration , mercury (programming language) , electrolyte , analytical chemistry (journal) , chromatography , electrochemistry , biochemistry , enzyme , computer science , programming language
A potentiometric procedure for cysteine thiol group concentration monitoring in media generat- ing free radicals was developed using a thiol specific silver-mercury electrode. Electrolytic depo - sition of mercury on a silver wire and treatment with 20 mM cysteine in 0.5 M NaOH were used to produce the electrode. A silver-chloride electrode in saturated KCl was the reference. A glass capillary with 1 M KNO3 in 1% agarose gel was the liquid junction. The electrode responded to cysteine concentration in the range from 0.01 to 20 mM yielding a perfect linear relationship for the dependence of log (cysteine) versus electrode potential (mV), with b0 (constant) = -373.43 (mV), b1 (slope) = -53.82 and correlation coefficient r 2 = 0.97. The electrode potential change per decade of cysteine concentration was 57 mV. The minimal measurable signal response was at a cysteine concentration of 0.01 mM. The signal CV amounted to 4-6% for cysteine concentrations of 0.01 to 0.05 mM and to less than 1% for cysteine concentrations of 0.5 to 20 mM. The response time ranged from about 100 s for cysteine concentrations of 0.01 to 0.1 mM to 30 s at higher cysteine concentrations. The standard curve reproducibility was the best at cysteine concentra- tions from 0.1 to 20 mM. In a reaction medium containing cysteine and copper(II)-histidine com- plex ((His-Cu)2+) solution in 55 mM phosphate buffer pH 7.4 the electrode adequately responded to changes in cysteine concentration. Beside cysteine, the silver-mercury electrode responded also to thiol groups of homocysteine and glutathione, however, the Nernst equation slope was about half of that for cysteine.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom