z-logo
open-access-imgOpen Access
[18F]ML-10 PET: Initial Experience in Glioblastoma Multiforme Therapy Response Assessment
Author(s) -
Matthew J. Oborski,
Charles M. Laymon,
Frank S. Lieberman,
Yongxian Qian,
Jan Drappatz,
James M. Mountz
Publication year - 2016
Publication title -
tomography
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.074
H-Index - 9
eISSN - 2379-139X
pISSN - 2379-1381
DOI - 10.18383/j.tom.2016.00175
Subject(s) - nuclear medicine , magnetic resonance imaging , medicine , positron emission tomography , glioblastoma , radiology , cancer research
The ability to assess tumor apoptotic response to therapy could provide a direct and prompt measure of therapeutic efficacy. 18 F-labeled 2-(5-fluoro-pentyl)-2-methyl-malonic acid ([ 18 F]ML-10) is proposed as a positron emission tomography (PET) apoptosis imaging radiotracer. This manuscript presents initial experience using [ 18 F]ML-10 PET to predict therapeutic response in 4 patients with human glioblastoma multiforme. Each patient underwent [ 18 F]ML-10 PET and contrast-enhanced magnetic resonance imaging (MRI) before (baseline) and at ∼2-3 weeks after therapy (early-therapy assessment). All PET and MRI data were acquired using a Siemens BioGraph mMR integrated PET/MRI scanner. PET acquisitions commenced 120 minutes after injection with 10 mCi of [ 18 F]ML-10. Changes in [ 18 F]ML-10 standard uptake values were assessed in conjunction with MRI changes. Time-to-progression was used as the outcome measure. One patient, ML-10 #4, underwent additional sodium-23 ( 23 Na) MRI at baseline and early-therapy assessment. Siemens 3 T Magnetom Tim Trio scanner with a dual-tuned ( 1 H- 23 Na) head coil was used for 23 Na-MRI, acquiring two three-dimensional single-quantum sodium images at two echo times (TE). Volume-fraction-weighted bound sodium concentration was quantified through pixel-by-pixel subtraction of the two single-quantum sodium images. In the cases presented, [ 18 F]ML-10 uptake changes were not clearly related to time-to-progression. We suggest that this may be because the tumors are undergoing varying rates of cell death and growth. Acquisition of complementary measures of tumor cell proliferation or viability may aid in the interpretation of PET apoptosis imaging.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom