z-logo
open-access-imgOpen Access
POTENTIOMETRIC STUDY FOR RAPID CONTINUOUS MONITORING OF TRACE LEVEL THIOCYANATE USING SOLID AND CONVENTIONAL TYPES PVC MEMBRANE SENSORS
Author(s) -
Ayman H. Kamel
Publication year - 2018
Publication title -
european chemical bulletin
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.131
H-Index - 5
ISSN - 2063-5346
DOI - 10.17628/ecb.2018.7.182-189
Subject(s) - detection limit , thiocyanate , potentiometric titration , chemistry , electrode , membrane , linear range , resorcinol , cyanide , chromatography , analytical chemistry (journal) , selectivity , potentiometric sensor , inorganic chemistry , organic chemistry , biochemistry , catalysis
A comparative study using two different thiocyanate electrode designs was conducted; a solid type electrode (type A) and conventional liquid inner contact called electrode (type B). The fabrication of these electrodes was based on Al (III) [4-(2-Pyridylazo) resorcinol] (Al/PAR) and Mg (II) phthalocyanine (MgPC) complexes as a charged carrier,aliquate 336S and TDMAC as ion exchangers in plasticized poly (vinyl chloride) membrane. Electrodes type (A) revealed significantly enhanced response towards SCN - ions with displayed near-Nernstian slope of -53.7-55.8 mV decade -1 over the concentration range 5.0x10 -6 -1.0x10 -2 mol L -1 and a detection limit of 0.4-3.7 µg mL -1 . Type (B) sensors revealed near-Nernstian potential response to SCN - with a slope of -45.9-62.4 mV decade -1 over a linear range of 5.0x10 -5 - 1.0x10 -2 mol L -1 and a detection limit of 0.12-0.3 µg mL -1 . Membrane sensors based on (Al/PAR) and (MgPC) using the so called "fixed interference method" (FIM) exhibited a good selectivity over different anions which differ significantly from the classical Hofmeister series.  All sensors were integrated in a flow system for continuous monitoring of thiocyanate under hydrodynamic mode of opration. The sensors revealed a frequency of ~ 54 samples h -1 . Application of the proposed sensors for SCN - determination in biological fluid samples such as saliva and urine collected from some non-smokers and smokers donors. Determination of cyanide content in electroplating wastewater samples after its conversion into thiocyanate was also applied. The results obtained from the proposed sensors were agreed with that obtained using the standard methods of thiocyanate and cyanide analysis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom