z-logo
open-access-imgOpen Access
KOMPOZİT İNLEY, İNDİREKT PORSELEN İNLEY VE CAD/CAM İNLEY SİSTEMİ İLE RESTORE EDİLEN DİŞLERİN KENAR SIZINTILARININ İNCELENMESİ: İN VİTRO ÇALIŞMA
Author(s) -
Ertuğrul Ercan,
Damla İBRAHİMOVA,
Mehmet Mustafa HAMİDİ
Publication year - 2015
Publication title -
atatürk üniversitesi diş hekimliği fakültesi dergisi
Language(s) - English
Resource type - Journals
eISSN - 2667-5161
pISSN - 1300-9044
DOI - 10.17567/dfd.56543
Subject(s) - cad , art , engineering , engineering drawing
Amac: Bu calismanin amaci; farkli yontemler ve ma- teryallerle restore edilen inley uygulamalarinin kenar sizintisi acisindan in vitro olarak degerlendirilmesidir. Gerec ve Yontem: Calismada; curuksuz ve restorasyonsuz 80 adet 3.molar insan disine sinif II (mezio-okluzal) inley kaviteler hazirlandi. Disler, her grupta 20 adet olacak sekilde dort gruba ayrildi. 1.Grup: Filtek Ultimate (3M ESPE, St. Paul, MN, ABD) kompozit, 2.Grup: Lava Ultimate CAD/CAM (3M ESPE, St. Paul, MN, ABD), 3.Grup: IPS e.max Press (Ivoclar Vivadent, Amherst, NY) seramik inleyler ve 4.Grup: IPS e.max CAD (Ivoclar Vivadent, Amherst, NY) inleyler hazirlandi. Bitirme ve polisaj islemlerinden sonra tum orneklere 5±1°C’de ve 55±1°C’de 10.000 kez termal siklus uygulandi. Tum orneklerde restorasyonun etrafindaki 1 mm’lik alan disinda kalan bolgeler iki kat tirnak cilasi ile kaplandi ve 24 saat sureyle % 0,5’lik bazik fuksin solusyonunda bekletildi. Kenar sizintisini degerlendirmek icin okluzo-gingival yonde longitudinal olarak kesildi. Boya penetrasyonu stereomikroskop altinda (30x buyutmede) incelendi ve skorlandi. Sonuclar Kruskal-Wallis, Mann-Whitney U ve Wilcoxon Signed Ranks testleri ile istatistiksel olarak degerlendirildi (Anlamlilik duzeyi p<0,05). Bulgular: Okluzal bolgede en az sizinti e.max CAD ve Lava Ultimate gruplarinda gozlendi. CAD/CAM yontemi ile hazirlanan gruplar, diger gruplara oranla okluzal bolgede anlamli derecede daha dusuk sizinti degerleri gostermistir (p=0,000). Gingival bolgedeki sizinti degerleri incelendiginde, gruplar arasinda anlamli bir fark bulunamamistir (p=0,825). Sonuc: Mikrosizinti degerleri kiyaslandiginda CAD/ CAM ile uretilen inley gruplari ozellikle okluzal bolgede daha basarili sonuclar verirken, servikal bolgede grup- lar arasinda anlamli bir farklilik bulunmadi. Bununla beraber, in vitro calismalarin in vivo calismalarla desteklenmesine ihtiyac vardir. Anahtar Sozcukler: CAD/CAM sistemi, direkt kompozit inley, indirekt porselen inley, mikrosizinti MARGINAL LEAKAGE EVALUATION OF COMPOSITE INLAY, INDIRECT PORCELAIN INLAY AND TEETH RESTORED WITH CAD/CAM SYSTEMS: IN VITRO STUDY ABSTRACT Aim: The aim of this study was to evaluate the in vitro marginal leakage of inlays performed with different methods and materials. Materials and Methods: In this study, class II mesio-occlusal cavities were prepared on 80 caries and restoration free human third molar teeth. The teeth were divided into four groups and 20 teeth each. 1. Group: Filtek Ultimate (3M ESPE, St. Paul, MN, ABD) direct composite inlays, 2.Group: Lava Ultimate CAD/CAM (3M ESPE, St. Paul, MN, ABD) inlays, 3.Group: IPS e.max Press (Ivoclar Vivadent, Amherst, NY) ceramic inlays and 4.Group: IPS e.max CAD (Ivoclar Vivadent, Amherst, NY) inlays were prepared. After finishing and polishing procedures 10.000 thermal cycles between 5±1°C and 55±1°C were applied to all specimens. All samples, except 1 mm around the restoration margin, were coated with two layers of nail varnish, and were suspended in 0.5 % basic fuchsine solution for 24 hours. To evaluate the microleakage, the teeth were cut longitudinally in occluso-gingival direction. The dye penetration was examined under a stereomicroscope (30x magni- fication) and scored. The results were statistically analyzed by using Kruskal-Wallis, Mann-Whitney U and Wilcoxon Signed Ranks tests (Significance level of p<0.05). Results: In occlusal part, lowest microleakage values were obtained in e.max CAD and Lava groups. CAD/CAM groups showed statistically significant lower microleakage values than the other groups in occlusal part (p=0,000). In gingival part, there were no significant difference between the groups (p=0,825). Conclusion: When microleakage values of occlusal regions were compared, CAD / CAM generated inlay groups gave better results; but in cervical regions, no significant difference was founded between the groups. However, there is a need to support the in vitro findings by in vivo studies. Key Words: CAD/CAM system, direct composite inlay, indirect porcelain inlay, microleakage .

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom