z-logo
open-access-imgOpen Access
Preparation of Sulfonated Poly (ethylene-co-tetrafluoroethylene-graft-styrene) Based Polymer Electrolyte Membranes for Fuel Cell by using Gamma Irradiation Technique
Author(s) -
Ambyah Suliwarno
Publication year - 2012
Publication title -
atom indonesia
Language(s) - English
Resource type - Journals
eISSN - 2356-5322
pISSN - 0126-1568
DOI - 10.17146/aij.2012.134
Subject(s) - etfe , tetrafluoroethylene , styrene , polystyrene , materials science , hexafluoropropylene , polymer chemistry , monomer , nuclear chemistry , grafting , membrane , polymer , chemistry , copolymer , composite material , layer (electronics) , biochemistry
Poly (ethylene-co-tetrafluoroethylene-graft-styrene-sulfonate) was successfully prepared by irradiation grafting of a styrene monomer into ethylenetetrafluoro-ethylene (ETFE) films and followed by sulfonation of the graft chains. Five film sheets of ETFE which having a size of 3 cm x 8 cm, thickness of 25 µm were packed in vacuum using a Y type tube filled with argon gas. The samples were irradiated using γ-rays with a dose of 15 kGy at 15 kGy/h. The iradiated samples were grafted by using styrene monomer at 60 o C for 1, 3, 5, 7 and 9 h, respectively. The grafted samples (ETFE-g-St) were washed with xylene to remove homopolymer of polystyrene, and then its degree of grafting (DG) was determined. Sulfonation was carried out by using 0.2 M chlorosulfonic acid in dichloroethane solution at a water bath of 60 o C for 6 h. Sulfonated samples (ETFE-g-St-SO 3 H) were washed with water to neutralize its acidity, and dried in a vacuum drier at 40 o C for 15 h. The dried sample was weighed as sulfonated sample in order to determine the degree of sulfonation (%DS). Membrane properties of EFTE-g-St-SO 3 H sample such as ion exchange capacity (IEC), proton conductivity in cross direction (σ 1 ), and in-plane direction (σ 11 ) were determined by using a HIOKI-3522 LCR HI tester. Durability test of samples were conducted in hot water and 3% H 2 O 2 respectively.. The proton conductivity measurement and durability of the membrane were compared to Nafion 112® as standard. The experimental results showed that the degree of grafting was increased with time of reaction for copolymerization, while %DS gave excellent results with an average of 92.7%. The IEC value was more affected by the %DG as compared to that of %DS effect. The average of σ l value of the sample was 0.055 S/cm, compared to σ 1  of Nafion112® that was 0.066 S/cm. The average of σ 11  of the sample was 0.18 S/cm, while the σ 11 of Nafion 112® was = 0.36 S/cm. The sample of SA004 with 53.49% DG was more stable than both the SA001 (21.48%DG) and SA003 (41.52% DG) in durability’s test of the samples against hot water (334 h resistance). On the peroxides test, all of samples were degraded at 114 h.  Received: 20 November 2011; Revised: 28 March 2012; Accepted: 30 April 2012

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom