z-logo
open-access-imgOpen Access
Validity and reliability of rectus femoris ultrasound measurements: Comparison of curved-array and linear-array transducers
Author(s) -
Kendra Hammond,
Jobby Mampilly,
Franco Laghi,
Amit Goyal,
Eileen G. Collins,
Conor McBurney,
Amal Jubran,
Martin J. Tobin
Publication year - 2014
Publication title -
the journal of rehabilitation research and development
Language(s) - English
Resource type - Journals
eISSN - 1938-1352
pISSN - 0748-7711
DOI - 10.1682/jrrd.2013.08.0187
Subject(s) - intraclass correlation , transducer , repeatability , reliability (semiconductor) , ultrasound , medicine , rectus femoris muscle , biomedical engineering , mathematics , acoustics , physical medicine and rehabilitation , physics , radiology , statistics , electromyography , clinical psychology , power (physics) , quantum mechanics , psychometrics
Muscle-mass loss augers increased morbidity and mortality in critically ill patients. Muscle-mass loss can be assessed by wide linear-array ultrasound transducers connected to cumbersome, expensive console units. Whether cheaper, hand-carried units equipped with curved-array transducers can be used as alternatives is unknown. Accordingly, our primary aim was to investigate in 15 nondisabled subjects the validity of measurements of rectus femoris cross-sectional area by using a curved-array transducer against a linear-array transducer-the reference-standard technique. In these subjects, we also determined the reliability of measurements obtained by a novice operator versus measurements obtained by an experienced operator. Lastly, the relationship between quadriceps strength and rectus area recorded by two experienced operators with a curved-array transducer was assessed in 17 patients with chronic obstructive pulmonary disease (COPD). In nondisabled subjects, the rectus cross-sectional area measured with the curved-array transducer by the novice and experienced operators was valid (intraclass correlation coefficient [ICC]: 0.98, typical percentage error [%TE]: 3.7%) and reliable (ICC: 0.79, %TE: 9.7%). In the subjects with COPD, both reliability (ICC: 0.99) and repeatability (%TE: 7.6% and 9.8%) were high. Rectus area was related to quadriceps strength in COPD for both experienced operators (coefficient of determination: 0.67 and 0.70). In conclusion, measurements of rectus femoris cross-sectional area recorded with a curved-array transducer connected to a hand-carried unit are valid, reliable, and reproducible, leading us to contend that this technique is suitable for cross-sectional and longitudinal studies.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom