Subject(s) - gait , prosthesis , biomechanics , medicine , gait cycle , ground reaction force , gait analysis , knee joint , physical medicine and rehabilitation , physical therapy , kinematics , surgery , anatomy , physics , classical mechanics
The C-Leg (Otto Bock, Duderstadt, Germany) is a microprocessor-controlled prosthetic knee that may enhance amputee gait. This intrasubject randomized study compared the gait biomechanics of transfemoral amputees wearing the C-Leg with those wearing a common noncomputerized prosthesis, the Mauch SNS (Ossur, Reykjavik, Iceland). After subjects had a 3-month acclimation period with each prosthetic knee, typical gait biomechanical data were collected in a gait laboratory. At a controlled walking speed (CWS), peak swing phase knee-flexion angle decreased for the C-Leg group compared with the Mauch SNS group (55.2 degrees +/- 6.5 degrees vs 64.41 degrees +/- 5.8 degrees , respectively; p = 0.005); the C-Leg group was similar to control subjects' peak swing knee-flexion angle (56.0 degrees +/- 3.4 degrees ). Stance knee-flexion moment increased for the C-Leg group compared with the Mauch SNS group (0.142 +/- 0.05 vs 0.067 +/- 0.07 N"m, respectively; p = 0.01), but remained significantly reduced compared with control subjects (0.477 +/- 0.1 N"m). Prosthetic limb step length at CWS was less for the C-Leg group compared with the Mauch SNS group (0.66 +/- 0.04 vs 0.70 +/- 0.06 m, respectively; p = 0.005), which resulted in increased symmetry between limbs for the C-Leg group. Subjects also walked faster with the C-Leg versus the Mauch SNS (1.30 +/- 0.1 vs 1.21 +/- 0.1 m/s, respectively; p = 0.004). The C-Leg prosthetic limb vertical ground reaction force decreased compared with the Mauch SNS (96.3 +/- 4.7 vs 100.3 +/- 7.5 % body weight, respectively; p = 0.0092).

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom