Increased peritoneal membrane transport is associated with decreased patient and technique survival for continuous peritoneal dialysis patients. The Canada-USA (CANUSA) Peritoneal Dialysis Study Group.
Author(s) -
David N. Churchill,
Kevin E. Thorpe,
Karl D. Nolph,
Prakash Keshaviah,
D.G. Oreopoulos,
Denis Pagé
Publication year - 1998
Publication title -
journal of the american society of nephrology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 4.451
H-Index - 279
eISSN - 1533-3450
pISSN - 1046-6673
DOI - 10.1681/asn.v971285
Subject(s) - peritoneal dialysis , peritoneal equilibration test , medicine , continuous ambulatory peritoneal dialysis , proportional hazards model , survival analysis , prospective cohort study , gastroenterology , urology , dialysis , surgery , ambulatory
The objective of this study was to evaluate the association of peritoneal membrane transport with technique and patient survival. In the Canada-USA prospective cohort study of adequacy of continuous ambulatory peritoneal dialysis (CAPD), a peritoneal equilibrium test (PET) was performed approximately 1 mo after initiation of dialysis; patients were defined as high (H), high average (HA), low average (LA), and low (L) transporters. The Cox proportional hazards method evaluated the association of technique and patient survival with independent variables (demographic and clinical variables, nutrition, adequacy, and transport status). Among 606 patients evaluated by PET, there were 41 L, 192 LA, 280 HA, and 93 H. The 2-yr technique survival probabilities were 94, 76, 72, and 68% for L, LA, HA, and H, respectively (P = 0.04). The 2-yr patient survival probabilities were 91, 80, 72, and 71% for L, LA, HA, and H, respectively (P = 0.11). The 2-yr probabilities of both patient and technique survival were 86, 61, 52, and 48% for L, LA, HA, and H, respectively (P = 0.006). The relative risk of either technique failure or death, compared to L, was 2.54 for LA, 3.39 for HA, and 4.00 for H. The mean drain volumes (liters) in the PET were 2.53, 2.45, 2.33, and 2.16 for L, LA, HA, and H, respectively (P < 0.001). After 1 mo CAPD treatment, the mean 24-h drain volumes (liters) were 9.38, 8.93, 8.59, and 8.22 for L, LA, HA, and H, respectively (P < 0.001); the mean 24-h peritoneal albumin losses (g) were 3.1, 3.9, 4.3, and 5.6 for L, LA, HA, and H, respectively (P < 0.001). The mean serum albumin values (g/L) were 37.8, 36.2, 33.8, and 32.8 for L, LA, HA, and H, respectively (P < 0.001). Among CAPD patients, higher peritoneal transport is associated with increased risk of either technique failure or death. The decreased drain volume, increased albumin loss, and decreased serum albumin concentration suggest volume overload and malnutrition as mechanisms. Use of nocturnal cycling peritoneal dialysis should be considered in H and HA transporters.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom