Effects of controlled blood cooling on hemodynamic stability and urea kinetics during high-efficiency hemodialysis.
Author(s) -
Allen Kaufman,
Alice T. Morris,
Valentina Lavarias,
Yijun Wang,
Jwh Leung,
M. B. Glabman,
Salim Yusuf,
A. L. LeVoci,
H.D. Polaschegg,
Nathan W. Levin
Publication year - 1998
Publication title -
journal of the american society of nephrology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 4.451
H-Index - 279
eISSN - 1533-3450
pISSN - 1046-6673
DOI - 10.1681/asn.v95877
Subject(s) - hemodialysis , dialysis , extracorporeal circulation , hemodynamics , extracorporeal , chemistry , medicine , cardiology
Although the use of cooled dialysate during hemodialysis is associated with stabilization of intradialytic BP, the effects of blood cooling on hemodynamics and urea kinetics in high-efficiency hemodialysis have not been completely studied. In particular, the effects of blood cooling have not been elucidated in very short-time, high K/V dialysis treatments, in which postdialysis urea rebound is maximized. In theory, blood cooling could increase urea compartmentalization during treatment and decrease dialysis efficacy. Measurements of cardiovascular hemodynamics and urea kinetics were performed in 15 patients (56 studies) during dialysis, using a blood temperature monitor with control of dialysate temperature. Dialysate temperature was adjusted to either lower the core temperature or raise the core temperature by, respectively, producing negative heat-energy exchange (cooled dialysis) or keeping heat-energy exchange in the extracorporeal circuit neutral (thermoneutral dialysis) so that energy was not transferred to or from the patient. Each subject was studied on both protocols, thereby allowing each individual to act as his own control. In cooled dialysis, heat-energy exchange in the extracorporeal circuit was -266+/-15 kJ per treatment, and dialysate temperature averaged 35.7+/-0.02 degrees C. In thermoneutral dialysis, heat-energy exchange in the extracorporeal circuit averaged 5+/-31 kJ per treatment, and dialysate temperature averaged 37.1+/-0.02 degrees C. Dialysate cooling resulted in a reduction in mean body temperature compared with thermoneutral therapy (-0.22+/-0.04 versus +0.31+/-0.05 degrees C). Cooling resulted in a greater increase in peripheral vascular resistance index (+515+/-160 versus + 114+/-92 dyn.sec/cm5 per m2), an increase in mean arterial pressure (+4+/-3 versus -4+/-4 mmHg), a reduction in the maximum intradialytic fall in mean arterial pressure (-10+/-2 versus -18+/-3, mmHg), and a reduction in staff interventions for hypotension or dialytic symptoms (6 of 28 versus 12 of 28 studies). These differences occurred without differences in the change in blood volume (-14.3+/-1.8% versus -13.9+/-2.2%) or cardiac index (-0.4+/-0.1 versus -0.4+/-0.2, L/min per m2). Urea rebound (37+/-4% versus 38+/-3%) and effective Kt/V (1.29+/-0.05 versus 1.32+/-0.06) were not different between groups. Thus, body temperature cooling can be used to stabilize BP and reduce intradialytic events requiring staff intervention without compromising the efficacy of treatment in high-efficiency dialysis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom