Proposal of framework for decision making of additional monitoring of eye lens dose for radiation workers
Author(s) -
Munehiko Kowatari,
Hiroshi Yoshitomi,
Tetsuya Ohishi,
Michio Yoshizawa
Publication year - 2019
Publication title -
progress in nuclear science and technology
Language(s) - English
Resource type - Journals
ISSN - 2185-4823
DOI - 10.15669/pnst.6.86
Subject(s) - eye lens , lens (geology) , radiation , computer science , medical physics , optometry , medicine , optics , physics
This work presents a framework of decision-making for additional monitoring of eye lens dose for radiation workers in reflect to the reduction of the annual dose limit of the eye lens dose. For a quantitative scheme to systematically estimate (non-) homogeneity of exposure, the proposed “homogeneity index (HI)” is introduced. The HIs were estimated by Monte Carlo calculations and found not to exceed up to 10 for γ-ray exposure situations. Applying the HI as a criterion of condition branching to decision-making process of additional monitoring of eye lens dose, proposed decision-making process was shown to cover entirely radiation workers required additional monitoring in the benchmark.