Successful explantation of ventricular assist device for systemic ventricular assistance in a patient with congenitally corrected transposition of the great arteries
Author(s) -
Tomoko Sugiura,
Hiromi Kurosawa,
Toshiharu Shinoka,
Akihiko Kawai
Publication year - 2006
Publication title -
interactive cardiovascular and thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.546
H-Index - 56
eISSN - 1569-9293
pISSN - 1569-9285
DOI - 10.1510/icvts.2006.139337
Subject(s) - great arteries , medicine , ventricle , ventricular assist device , cardiology , ventricular function , transposition (logic) , tricuspid valve , right ventricular failure , surgery , heart failure , linguistics , philosophy
We report a case of a 13-year-old boy with congenitally corrected transposition of the great arteries after conventional repair who underwent an implantation of ventricular assist device (VAD) due to right (systemic) ventricular failure after tricuspid valve replacement. The anatomical right ventricle (systemic ventricle) was completely unloaded and the function improved over time under LVAD. He had an explantation of the VAD due to bacteremia 43 days after implantation, and his clinical condition improved significantly.