z-logo
open-access-imgOpen Access
Safety and Outcomes of Transcatheter Closure of Patent Ductus Arteriosus in Children With Pulmonary Artery Hypertension
Author(s) -
Arash Salavitabar,
Usha Krishnan,
Mariel E. Turner,
Julie A. Vincent,
Alejandro Torres,
Matthew A. Crystal
Publication year - 2020
Publication title -
texas heart institute journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.373
H-Index - 53
eISSN - 1526-6702
pISSN - 0730-2347
DOI - 10.14503/thij-19-6982
Subject(s) - medicine , ductus arteriosus , pulmonary artery , pulmonary hypertension , interquartile range , left pulmonary artery , cardiac catheterization , cardiology , embolization , vascular resistance , surgery , blood pressure
To investigate whether transcatheter device closure of patent ductus arteriosus (PDA) is safe in children with pulmonary artery hypertension, we retrospectively analyzed our experience with 33 patients who underwent the procedure from January 2000 through August 2015. Pulmonary artery hypertension was defined as a pulmonary vascular resistance index (PVRI) >3 WU · m2. All 33 children (median age, 14.5 mo; median weight, 8.1 kg) underwent successful closure device implantation and were followed up for a median of 17.2 months (interquartile range [IQR], 1.0-63.4 mo). During catheterization, the median PVRI was 4.1 WU · m2 (IQR, 3.6-5.3 WU · m2), and the median mean pulmonary artery pressure was 38.0 mmHg (IQR, 25.5-46.0 mmHg). Premature birth was associated with pulmonary vasodilator therapy at time of PDA closure ( P=0.001) but not with baseline PVRI (P=0.986). Three patients (9.1%) had device-related complications (one immediate embolization and 2 malpositions). Two of these complications involved embolization coils. Baseline pulmonary vasodilator therapy before closure was significantly associated with intensive care unit admission after closure (10/12 [83.3%] with baseline therapy vs 3/21 [14.3%] without; P <0.001). Of 11 patients receiving pulmonary vasodilators before closure and having a device in place long-term, 8 (72.7%) were weaned after closure (median, 24.0 mo [IQR, 11.0-25.0 mo]). We conclude that transcatheter PDA closure can be performed safely in many children with pulmonary artery hypertension and improve symptoms, particularly in patients born prematurely. Risk factors for adverse outcomes are multifactorial, including coil use and disease severity. Multicenter studies in larger patient populations are warranted.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom