Radiation Doses in Patients Undergoing Computed Tomographic Coronary Artery Calcium Evaluation With a 64-Slice Scanner Versus a 256-Slice Scanner
Author(s) -
Paul Madaj,
Li Dong,
Rine Nakanishi,
Daniele Andreini,
Gianluca Pontone,
Edoardo Conte,
Rachael O’Rourke,
Christian HamiltonCraig,
Manojimmagadda,
Nicholas Kim,
Badiha Fatima,
Christopher Dailing,
Kashif Shaikh,
Chandana Shekar,
Ju Hwan Lee,
Matthew J. Budoff
Publication year - 2022
Publication title -
texas heart institute journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.373
H-Index - 53
eISSN - 1526-6702
pISSN - 0730-2347
DOI - 10.14503/thij-18-6793
Subject(s) - medicine , scanner , computed tomographic , coronary artery calcium , nuclear medicine , computed tomographic angiography , radiology , radiation dose , computed tomography , angiography , artificial intelligence , computer science
Computed tomographic coronary artery calcium scanning enables cardiovascular risk stratification; however, exposing patients to high radiation levels is an ongoing concern. New-generation computed tomographic systems use lower radiation doses than older systems do. To quantify comparative doses of radiation exposure, we prospectively acquired images from 220 patients with use of a 64-slice GE LightSpeed VCT scanner (control group, n=110) and a 256-slice GE Revolution scanner (study group, n=110). The groups were matched for age, sex, and body mass index; statistical analysis included t tests and linear regression. The mean dose-length product was 21% lower in the study group than in the control group (60.2 ± 27 vs 75.9 ± 22.6 mGy·cm; P <0.001) and also in each body mass index subgroup. Similarly, the mean effective radiation dose was 21% lower in the study group (0.84 ± 0.38 vs 1.06 ± 0.32 mSv) and lower in each weight subgroup. After adjustment for sex, women in the study group had a lower dose-length product (50.4 ± 23.4 vs 64.7 ± 27.6 mGy·cm) than men did and received a lower effective dose (0.7 ± 0.32 vs 0.9 ± 0.38 mSv) (P=0.009). As body mass index and waist circumference increased, so did doses for both scanners. Our study group was exposed to radiation doses lower than the previously determined standard of 1 mSv, even after adjustment for body mass index and waist circumference. In 256-slice scanning for coronary artery calcium, radiation doses are now similar to those in lung cancer screening and mammography.