Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study
Author(s) -
Ehsan Parsa,
Sepideh Saroukhani,
Fereshteh Majlessi,
Hamidreza Poorhosseini,
Masoumeh Lofti-Tokaldany,
Arash Jalali,
Mojtaba Salarifar,
Ebrahim Nematipour,
Mohammad Alidoosti,
Hassan Aghajani,
Alireza Amirzadegan,
Seyed Ebrahim Kassaian
Publication year - 2016
Publication title -
texas heart institute journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.373
H-Index - 53
eISSN - 1526-6702
pISSN - 0730-2347
DOI - 10.14503/thij-14-4997
Subject(s) - medicine , everolimus , percutaneous coronary intervention , myocardial infarction , stent , hazard ratio , surgery , population , clinical endpoint , cardiology , confidence interval , randomized controlled trial , environmental health
We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421–1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom