Evaluation of biosimilarity of RinGlar® (GEROPHARM LLC, Russia) and Lantus® (Sanofi-Aventis Deutschland GmbH, Germany) using the euglycemic hyperinsulinemic clamp technique in patients with type 1 diabetes: double-blind randomized clinical trial
Author(s) -
Alexander Yur'evich Mayorov,
Р. В. Драй,
Т. Л. Каронова,
Ольга Ильинична Авдеева,
И. Е. Макаренко,
Ekaterina Koksharova,
Ekaterina Е. Mishina,
Yu. A. Sevastyanova,
О. В. Афонькина
Publication year - 2020
Publication title -
diabetes mellitus
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.155
H-Index - 12
eISSN - 2072-0378
pISSN - 2072-0351
DOI - 10.14341/dm10095
Subject(s) - medicine , insulin glargine , pharmacodynamics , diabetes mellitus , insulin , type 2 diabetes , crossover study , type 1 diabetes , pharmacokinetics , placebo , pharmacology , endocrinology , alternative medicine , pathology
Background: Prevention of the development of micro-and macrovascular complications in patients with diabetes melli-tus (DM) encouraged the search for insulin analogues that allow imitating, as close as possible, a normal physiological insulin secretion in healthy people. Biosimilars (bioanalogues of reference products) play an important role in the full provision with high-quality insulin medications throughout patients. The program of clinical trials of insulin bioanalogues includes pharmacology studies: pharmacokinetics (PK), pharmacodynamics (PD) and clinical safety research. Aims: To test whether RinGlar® (GEROPHARM LLC, Russia) and Lantus® (Sanofi-Aventis Deutschland GmbH, Germany) have similar PK and PD profiles in a hyperinsulinemic euglycaemic clamp (HEC) setting in patients with type 1 diabetes mellitus. Permission of the Ministry of Health of the Russian Federation No. 150 of 03/03/2016. Materials and methods : The study was conducted in 42 patients with type 1 diabetes aged 18 to 65 years. A doubleblind, randomized, crossover study of comparative PK and PD of drugs was chosen as a study design. The investigational products were injected after achieving a state of euglycemia before the HEC in a single dose of 0.6 U/kg subcutaneously into the subcutaneous fat of the anterior abdominal wall. During the study, regular blood sampling was performed, the amount of insulin glargine in the samples was determined by ELISA. The results are used to calculate the PK parameters and generate the concentration-time curves. The glucose infusion rate was corrected based on the measurement of glycemia. These data are used to calculate the PD parameters. Results: RinGlar® and Lantus® interventions have comparable PK and PD profiles in HEC setting in patients with type 1 diabetes. This is confirmed by the similarity of the main PK/PD parameters, PK/PD curves, and comparable safety. The confidence intervals of the geometric mean ratio were 81.02% - 120.62% for the PK parameter AUC ins0-T , and 85.43% - 115.64% for the PD-parameter AUC GIR0_T , which fall within the specified limits of 80% - 125% to establish comparability between drugs. Conclusions: Results of the clinical trial demonstrate the biosimilarity of the products RinGlar® and Lantus®.