z-logo
open-access-imgOpen Access
Efeito da desinfecção associada à escovação na rugosidade superficial de resina acrílica termopolimerizável
Author(s) -
Mariana Diehl Figueiredo,
Lafayette Nogueira,
José Renato Cavalcanti Queiroz,
Carlos Augusto Pavanelli
Publication year - 2012
Publication title -
brazilian dental science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.153
H-Index - 6
ISSN - 2178-6011
DOI - 10.14295/bds.2011.v14i1/2.682
Subject(s) - chemistry , physics , nuclear chemistry
O objetivo desse estudo e avaliar o efeito da desinfeccao associada a escovacao na rugosidade (Ra e Rz) superficial de resina acrilica termopolimerizavel. Cinquenta cilindros de resina acrilica (Lucitone 550 Dentsply) de dimensoes 0,5 mm x 0,5 mm foram confeccionados, utilizando-se o ciclo termico curto de polimerizacao (73oC por 90 min, seguidos por imersao em agua a 94oC durante 30 min), de acordo com as instrucoes do fabricante. Os especimes termopolimerizados foram imersos em agua destilada a 37 ±1oC por 48 horas e divididos em 5 grupos (n=10) de acordo com o metodo de desinfeccao: GrControle- sem desinfeccao e sem escovacao; Gr1-agua destilada seguido de escovacao; Gr2- hipoclorito de Sodio 1% seguido de escovacao; Gr3- gluconato de clorexidina 2% seguido de escovacao, e G4- perborato de sodio a 3,78% seguido de escovacao. Os grupos foram imersos por 5 min nas solucoes correspondentes antes do ciclo de escovacao (10.000 ciclos). Foram analisados em rugosimetro de contato os valores para Ra e Rz. Os resultados foram analisados estatisticamente pelo metodo ANOVA e as medias comparadas pelo teste de Tukey (α=0,05). As medias obtidas para o Ra e Rz respectivamente foram: Gr controle 0,16 (0,03) e 0,77 (0,21); Gr1 0,3 (0,13) e 1,25 (0,62); Gr2 0,24(0,09) e 1,02 (0,4); Gr3 0,34 (0,14) e 1,45(0,55); Gr4 0,38(0,14) e 1,7(0,65). O teste ANOVA revelou que a rugosidade para os dois parâmetros foi significativamente afetada pela abrasao provocada pela escovacao com dentifricio (PRa=0,0009; PRz=0,0021). Pode-se concluir que a escovacao associada a desinfeccao com hipoclorito de sodio produziu menor efeito sobre a rugosidade da superficie da resina acrilica que os demais desinfetantes testados.(AU) The aim of this study was to evaluate the effect of disinfection associated to brushing the superficial crease (Ra and Rz) of heat-polymerized acrylic resin. Fifty cylinders of 0.5mm x o.5mm acrylic resin (Lucitone 550 Dentsply) were produced by using the short thermal cycle of polymerization (73oC for 90 minutes and then immersion on water at the temperature of 94oC for 30 minutes), according to the manufacturerAEs instructions. The thermo-polymerized samples were immersed in distilled water at the temperature of 37oC (plus or minus 1oC) for 48 hours and divided into 5 groups (n=10) according to the disinfection method, that is: GrControl u no chemical disinfection nor brushing; Gr1 u distilled water and brushing; Gr2 u sodium hypoclorite 1% and brushing; Gr3 u chlorexidine gluconate 2% and brushing and G4 u sodium perborate 3,78% and brushing. The groups were immersed for 5 minutes before brushing cycle (10.000 cycles) and the values for Ra and Rz were analyzed with crease contact measuring instrument(contact profilometer). Results were statistically analyzed by the ANOVA method. The arithmetic means were compared by the Tukey test (ά=0.05). RESULTS: The arithmetic means obtained for Ra and Rz were : GrControl 0.16(0.03) and 0.77 (0.21); Gr1 0.3(0.13) and 1.25(0.62); Gr2 0.24(0.09) and 1.02(0.4); Gr3 0.34(0.14) and 1.45(0.55); Gr4 0.38(0.14) and 1.7(0.65) . The ANOVA test revealed that the roughness for the two parameters was significantly affected by brushing with toothpaste (PRa =0.0009; PRz=0.0021) .Tooth brushing together with sodium hypoclorite results in a lessened effect over the surface crease of the acrylic resin than other tested disinfectants

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom