Author(s) -
Christina E. Higgins,
Patricia Neybold,
Marcella B Holdridge,
Catherine R Barnes,
Yan Dong,
Michael A. Reeve,
Vinita Mathur,
James Weisberger,
Vincent Linder
Publication year - 2018
Publication title -
the journal of applied laboratory medicine
Language(s) - English
Resource type - Journals
eISSN - 2576-9456
pISSN - 2475-7241
DOI - 10.1373/jalm.2017.024612
Subject(s) - analyte , prostate cancer , medicine , prostate specific antigen , clinical practice , population , chromatography , urology , chemistry , cancer , environmental health , family medicine
Background The 4Kscore Test determines a personalized risk score for aggressive prostate cancer by combining the blood sample measurements of total prostate-specific antigen (tPSA), free PSA (fPSA), intact PSA (iPSA), and human kallikrein-related peptidase 2 (hK2) with patient clinical information to generate the patient risk's score; thus, accuracy and precision of the 4Kscore depend on the reliability of these measurements. Although tPSA and fPSA are measured on a Food and Drug Administration (FDA)-approved platform, the performance of the iPSA and hK2 assays in the clinical setting has not previously been reported. Methods Analytical performance was determined for the iPSA and hK2 assays in both serum and EDTA plasma, according to Clinical and Laboratory Standards Institute guidelines. Equivalence of the 4Kscore in both sample matrices was demonstrated in a 353-patient clinical cohort, and the stability of endogenous iPSA and hK2 for at least 3 days was demonstrated in a smaller subset. Results Intralaboratory and interlaboratory precision of the iPSA and hK2 assays in both matrices was comparable with that of FDA-approved tPSA and fPSA assays (<18% for iPSA; <8% for hK2). The picogram per milliliter sensitivity and wide dynamic range of the iPSA and hK2 assays allowed for accurate measurements in the target population. The 4Kscore generated in either matrix up to 3 days after collection is equivalent to that measured within 24 h of collection (Passing–Bablok slope 95% CI: plasma, 0.999–1.034; serum, 0.997–1.040). Conclusions The robust performance of component assays and reliable stability of the endogenous analytes in clinical samples proven here ensures an accurate 4Kscore Test result.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom