z-logo
open-access-imgOpen Access
Rapid Quantification of Medroxyprogesterone Acetate (MPA) in Human Plasma by LC-MS/MS
Author(s) -
Pamela Hummert,
Madhuri Manohar,
Wutyi Aung,
Mark A. Marzinke
Publication year - 2016
Publication title -
the journal of applied laboratory medicine
Language(s) - English
Resource type - Journals
eISSN - 2576-9456
pISSN - 2475-7241
DOI - 10.1373/jalm.2016.020511
Subject(s) - chromatography , bioanalysis , chemistry , medroxyprogesterone acetate , medroxyprogesterone , selected reaction monitoring , sample preparation , mass spectrometry , tandem mass spectrometry , hormone , biochemistry
Background Medroxyprogesterone acetate (MPA) is a common contraceptive agent taken both orally and as a subcutaneous or intramuscular injection. Current LC-MS/MS methods for MPA quantification require large sample volumes and low-throughput analytical run times. Therefore, there are opportunities to improve upon existing methods for MPA quantification. Methods MPA was extracted from 600 μL plasma, evaporated to dryness, and the reconstituted solution was injected onto a Waters Acquity liquid chromatography (LC) system via an Agilent Zorbax Eclipse-Plus C18 2.1 × 50 mm (5.0 μm) column. MPA and its internal standard were monitored on a QTRAP® 5500 mass analyzer operated in positive ionization mode. The method was validated according to the Food and Drug Administration Bioanalytical Method Validation guidelines. Results The analytical measuring range of the assay was 200–10 000 pg/mL. QC samples prepared at the lower limit of quantification (LLOQ; 200 pg/mL) and low (600 pg/mL), mid (1750 pg/mL), and high (8500 pg/mL) levels showed interassay precision and accuracy ≤15.2% and ≤±9.6%, respectively. Stability-challenged samples yielded ≤15% from freshly prepared samples. Dilutional and matrix effects studies were also acceptable. The assay was also assessed in participants prescribed depot medroxyprogesterone acetate; observed concentrations were within the dynamic range of the assay. Conclusions An LC-MS/MS method for the quantification of MPA in plasma has been developed and validated. The described method is sufficiently sensitive and robust to quantify MPA in plasma and meets the criteria to support clinical trials.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom