Commutability of a Whole-Blood External Quality Assessment Material for Point-of-Care C-Reactive Protein, Glucose, and Hemoglobin Testing
Author(s) -
Tone Bukve,
Sverre Sandberg,
Wenche S. Vie,
Una Ørvim Sølvik,
Nina Gade Christensen,
Anne Stavelin
Publication year - 2019
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2018.300202
Subject(s) - external quality assessment , medicine , analyte , point of care , point of care testing , chromatography , chemistry , pathology
BACKGROUND The optimal situation in external quality assessment (EQA) is to use commutable materials. No previous study has examined the commutability of a whole-blood material for point-of-care (POC) testing. The aim of this study was to determine the commutability of the Norwegian Quality Improvement of Laboratory Examinations (Noklus) organization's “in-house” whole-blood EQA material for C-reactive protein (CRP), glucose, and hemoglobin for frequently used POC instruments in Norway and to determine the possibility of using a common target value for each analyte. METHODS The study was performed according to the Clinical and Laboratory Standards Institute guidelines. The EQA material was pooled stabilized EDTA venous whole-blood containing different concentrations of the analytes. The EQA material and native routine patient samples were analyzed using 17 POC and 3 hospital instruments. The commutability was assessed using Deming regression analysis with 95% prediction intervals for each instrument comparison. RESULTS The EQA material was commutable for all CRP and hemoglobin POC instruments, whereas for glucose the material was commutable for all POC instruments at the lowest concentration analyzed [126.0 mg/dL (7.0 mmol/L)] and for 3 POC instruments at all of the concentrations analyzed. CONCLUSIONS Noklus EQA participants using CRP and hemoglobin POC instruments now receive results that are compared with a reference target value, whereas the results for participants using glucose POC instruments are still compared with method-specific target values. Systematic deviations from a reference target value for the commutable glucose POC instruments can be calculated, and this additional information can now be offered to these participants and to the manufacturers.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom