Clinical Assay for AFP-L3 by Using Multiple Reaction Monitoring–Mass Spectrometry for Diagnosing Hepatocellular Carcinoma
Author(s) -
Hyunsoo Kim,
Areum Sohn,
Injoon Yeo,
Su Jong Yu,
JungHwan Yoon,
Youngsoo Kim
Publication year - 2018
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2018.289702
Subject(s) - hepatocellular carcinoma , selected reaction monitoring , chemistry , biomarker , chromatography , detection limit , mass spectrometry , tandem mass spectrometry , medicine , biochemistry
BACKGROUND Lens culinaris agglutinin-reactive fraction of α-fetoprotein (AFP-L3) is a serum biomarker for hepatocellular carcinoma (HCC). AFP-L3 is typically measured by liquid-phase binding assay (LiBA). However, LiBA does not always reflect AFP-L3 concentrations because of its low analytical sensitivity. Thus, we aimed to develop an analytically sensitive multiple reaction monitoring–mass spectrometry (MRM-MS) assay to quantify AFP-L3 in serum. METHODS The assay entailed the addition of a stable isotope-labeled internal standard protein analog, the enrichment of AFP using a monoclonal antibody, the fractionation of AFP-L3 using L. culinaris agglutinin lectin, deglycosylation, trypsin digestion, online desalting, and MRM-MS analysis. The performance of the MRM-MS assay was compared with that of LiBA in 400 human serum samples (100 chronic hepatitis, 100 liver cirrhosis, and 200 HCC). Integrated multinational guidelines were followed to validate the assay for clinical implementation. RESULTS The lower limit of quantification of the MRM-MS assay (0.051 ng/mL) for AFP-L3 was less than that of LiBA (0.300 ng/mL). Thus, AFP-L3, which was not observed by LiBA in HCC samples (n = 39), was detected by the MRM-MS assay, improving the clinical value of AFP-L3 as a biomarker by switching to a more analytical sensitive platform. The method was validated, meeting all the criteria in integrated multinational guidelines. CONCLUSIONS Because of the lower incidence of false-negative findings, the MRM-MS assay is more suitable than LiBA for early detection of HCC.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom