Blood Sample Transportation by Pneumatic Transportation Systems: A Systematic Literature Review
Author(s) -
Mads Nybo,
Merete Eis Lund,
Kjell Titlestad,
Christian Ulrik Maegaard
Publication year - 2017
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2017.280479
Subject(s) - thromboelastometry , medicine , systematic review , intensive care medicine , emergency medicine , sample (material) , medline , surgery , whole blood , chemistry , biochemistry , chromatography
BACKGROUND Pneumatic transportation systems (PTSs) are increasingly used for transportation of blood samples to the core laboratory. Many studies have investigated the impact of these systems on different types of analyses, but to elucidate whether PTSs in general are safe for transportation of blood samples, existing literature on the subject was systematically assessed. METHODS A systematic literature review was conducted following the preferred reporting items for systematic reviews and metaanalyses (PRISMA) Statement guidelines to gather studies investigating the impact of PTS on analyses in blood samples. Studies were extracted from PubMed and Embase. The search period ended November 2016. RESULTS A total of 39 studies were retrieved. Of these, only 12 studies were conducted on inpatients, mainly intensive care unit patients. Blood gases, hematology, and clinical chemistry were well investigated, whereas coagulation, rotational thromboelastometry, and platelet function in acutely ill patients were addressed by only 1 study each. Only a few parameters were affected in a clinically significant way (clotting time parameter in extrinsic system thromboelastometry, pO2 in blood gas, multiplate analysis, and the hemolysis index). CONCLUSIONS Owing to their high degree of heterogeneity, the retrieved studies were unable to supply evidence for the safety of using PTSs for blood sample transportation. In consequence, laboratories need to measure and document the actual acceleration forces in their existing PTS, instituting quality target thresholds for these measurements such as acceleration vector sums. Computer modeling might be applied to the evaluation of future PTS installations. With the increasing use of PTS, a harmonized, international recommendation on this topic is warranted.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom