Quantification of BK Virus Standards by Quantitative Real-Time PCR and Droplet Digital PCR Is Confounded by Multiple Virus Populations in the WHO BKV International Standard
Author(s) -
Allen C. Bateman,
Alexander L. Greninger,
Ederlyn E. Atienza,
Ajit P. Limaye,
Keith R. Jerome,
Linda Cook
Publication year - 2017
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2016.265512
Subject(s) - digital polymerase chain reaction , virology , bk virus , real time polymerase chain reaction , biology , primer (cosmetics) , concordance , polyomavirus infections , virus , polymerase chain reaction , microbiology and biotechnology , genetics , chemistry , gene , organic chemistry , kidney transplantation , kidney
BACKGROUND The WHO recently released a BK virus (BKV) international standard. This study evaluated the WHO international standard and commercially available BKV standards by quantitative real-time PCR (qPCR) and droplet digital PCR (ddPCR). METHODS WHO, Exact Diagnostics, Acrometrix, and Zeptometrix BKV standards were tested by qPCR and ddPCR. Two preparations of NIST BKV clones were also tested. Nucleic acid was extracted with the Roche MP96 and MPLC, followed by quantification in duplicate. To resolve discrepancies, we sequenced the WHO and NIST materials. RESULTS Manufacturers' expected copies/mL were close to WHO IU/mL: linear regression of qPCR data revealed 1.12 Exact copies/IU, 0.76 Acrometrix copies/IU, and 0.70 Zeptometrix copies/IU. For ddPCR, similar concentrations were measured when either the VP1 region or the T region was targeted, and concentrations were almost 2-fold higher when both regions were targeted simultaneously. ddPCR results for the VP1 and T regions were similar for all commercial standards, but targeting the T region of the WHO standard led to a 4-fold lower result than the VP1 region. Next-generation sequencing revealed no primer or probe mismatches. However, large differences in coverage across the WHO standard and junctional reads were observed, indicating subpopulations of the WHO standard with deletions in the T region. CONCLUSIONS BKV standards showed concordance among providers, but the WHO standard contains subpopulations of viruses with various deletions in the T region. PCR results will vary depending on which region of the WHO standard is targeted.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom