z-logo
open-access-imgOpen Access
How Well Do Laboratories Adhere to Recommended Clinical Guidelines for the Management of Myocardial Infarction: The CARdiac MArker Guidelines Uptake in Europe Study (CARMAGUE)
Author(s) -
Paul Collinson,
Angelika HammererLercher,
Janne Suvisaari,
Fred S. Apple,
R H Christenson,
Kari Pulkki,
Marja P. van DieijenVisser,
Christopher J. Duff,
H Baum,
Ana Stavljenić-Rukavina,
Kristin M. Aakre,
Michel R. Langlois,
Sanja Stanković,
Päivi Laitinen
Publication year - 2016
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2016.259515
Subject(s) - medicine , myocardial infarction , troponin , biomarker , european union , business , chemistry , biochemistry , economic policy
BACKGROUND We undertook an assessment of current use of evidence-based guidelines for the use of cardiac biomarkers in Europe (EU) and North America (NA). METHODS In 2013–2014 a web-based questionnaire was distributed via NA and EU biochemical societies. Questions covered cardiac biomarkers measured, analytical methods used, decision thresholds, and use of decision-making protocols. Results were collated using a central database and analyzed using comparative and descriptive nonparametric statistics. RESULTS In EU, returns were obtained from 442 hospitals, 50% central or university hospitals, and 39% from local hospitals from 35 countries with 395/442 (89%) provided an acute service. In NA there were 91 responses (63.7% central or university hospitals, 19.8% community hospitals) with 76/91 (83.5%) providing an acute service. Cardiac troponin was the preferred cardiac biomarker in 99.5% (EU) and 98.7% (NA), and the first line marker in 97.7% (EU) and 97.4% (NA). There were important differences in the choice of decision limits and their derivations. The origin of the information was also significantly different, with EU vs NA as follows: package insert, 61.9% vs 40%; publications, 17.1% vs 15.0%; local clinical or analytical validation choice, 21.0% vs 45.0%; P = 0.0003. CONCLUSIONS There are significant differences between EU and NA use of cardiac biomarkers. This probably relates to different availability of assays between EU and NA (such as high-sensitivity troponin assays) and different laboratory practices on assay introduction (greater local evaluation of assay performance occurred in NA).