z-logo
open-access-imgOpen Access
Stability of i-Stat EC6+ Cartridges: Effect of Storage Temperature on Shelf Life
Author(s) -
Myra D. Smith,
Janis Davis-Street,
Dick S. Calkins,
Jeannie L. Nillen,
Scott M. Smith
Publication year - 2004
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2003.028936
Subject(s) - cartridge , stat , shelf life , chromatography , chemistry , biochemistry , food science , materials science , metallurgy , apoptosis , stat3
Point-of-care testing is a valuable tool in many settings, including remote environments (1). The i-STAT Portable Clinical Blood Analyzer (i-STAT Corp.) has been tested extensively and has been used during spaceflight as both a research (2)(3) and a clinical(4) tool. One disadvantage of the Portable Clinical Blood Analyzer is the requirement for refrigerated storage for consumables (ambient storage is limited to 2 weeks). The effects of re-refrigeration after transient ambient storage are undocumented, but this is discouraged by the manufacturer.We determined the effects of long-term ambient storage and the effects of re-refrigeration on the performance of i-STAT EC6+ cartridges. Cartridges were stored under one of three treatment conditions: controlled temperature (refrigerated; 2–8 °C), room temperature (18–25 °C), or re-refrigerated. The re-refrigerated cartridges started the study at room temperature and were placed in the refrigerator after a specified number of days. For example, cartridges in the re-refrigerated 16-day group were held at room temperature for 16 days and then were placed in the refrigerator. Subsets were analyzed on study day 23, and after 1 month, 2 months, and so forth.We used two levels of aqueous controls (Bionostics Corp.) and two levels of blood controls (Hematronix). Each group consisted of 20 cartridges: 6 Bionostics level 1 controls, 6 Bionostics level 3, 4 Hematronix low controls, and 4 Hematronix high controls. Cartridges and aqueous controls were single lots; blood controls were from three lots (expiration constraints). The limit ranges (levels 1 and 3, respectively) of each lot of each control (from package inserts) were as follows: pH, 7.130–7.230 and 7.647–7.747; ionized calcium (iCa), 1.47–1.69 and 0.71–0.87 mmol/L; glucose, 2.2–3.2 and 13.4–19.8 mmol/L; sodium, 116–124 and 156–166 mmol/L; and potassium, 2.0–2.8 and 5.8–6.8 mmol/L. The overall hematocrit control limit range was 26–30% packed cell volume (PCV) for the …

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom