Lower plasma insulin levels during overnight closed-loop in school children with type 1 diabetes: Potential advantage? A randomized cross-over trial
Author(s) -
Ulrike Schierloh,
Malgorzata E. Wilinska,
Ineke Pit-Ten Cate,
Petra Baumann,
Roman Hovorka,
Carine de Beaufort
Publication year - 2019
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0212013
Subject(s) - insulin , medicine , hypoglycemia , diabetes mellitus , type 1 diabetes , randomized controlled trial , type 2 diabetes , insulin pump , endocrinology , closed loop , control engineering , engineering
Background Studies have shown that overnight closed-loop insulin delivery can improve glucose control and reduce the risk of hypoglycemia and hence may improve metabolic outcomes and reduce burden for children with type 1 diabetes and their families. However, research so far has not reported insulin levels while comparing closed-loop to open-loop insulin delivery in children. Therefore, in this study we obtained glucose levels as well as plasma insulin levels in children with type 1 diabetes to evaluate the efficacy of a model—based closed-loop algorithm compared to an open-loop administration. Methods Fifteen children with type 1 diabetes, 6–12 years, participated in this open-label single center study. We used a randomized cross over design in which we compared overnight closed-loop insulin delivery with sensor augmented pump therapy for two nights in both the hospital and at home (i.e., 1 night in-patient stay and at home per treatment condition). Only during the in-patient stay, hourly plasma insulin and blood glucose levels were assessed and are reported in this paper. Results Results of paired sample t -tests revealed that although plasma insulin levels were significantly lower during the closed-loop than in the open-loop (Mean difference 36.51 pmol/l; t (13) = 2.13, p = .03, effect size d = 0.57), blood glucose levels did not vary between conditions (mean difference 0.76 mmol/l; t (13) = 1.24, p = .12, d = 0.37). The administered dose of insulin was significantly lower during the closed-loop compared with the open-loop ( mean difference 0.10 UI; t (12) = 2.45, p = .02, d = 0.68). Conclusions Lower insulin doses were delivered in the closed-loop, resulting in lower plasma insulin levels, whereby glucose levels were not affected negatively. This suggests that the closed-loop administration is better targeted and hence could be more effective.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom