Clinical Utility of a Novel Molecular Assay in Various Combination Strategies with Existing Methods for Diagnosis of HIV-Related Tuberculosis in Uganda
Author(s) -
Willy Ssengooba,
Lydia Nakiyingi,
Derek T. Armstrong,
Frank Cobelens,
David Alland,
Yukari C. Manabe,
Susan E. Dorman,
Jerrold J. Ellner,
Moses Joloba
Publication year - 2014
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0107595
Subject(s) - medicine , tuberculosis , sputum , mycobacterium tuberculosis , gold standard (test) , tuberculosis diagnosis , sputum culture , pathology
Background Low income, high-tuberculosis burden, countries are considering selective deployment of Xpert MTB/RIF assay (Xpert) due to high cost per test. We compared the diagnostic gain of the Xpert add-on strategy with Xpert replacement strategy for pulmonary tuberculosis diagnosis among HIV-infected adults to inform its implementation. Methods The first diagnostic sputum sample of 424 HIV-infected adults (67% with CD4 counts ≤200/mm 3 ) suspected for tuberculosis was tested by direct Ziehl-Neelsen (DZN) and direct fluorescent microscopy (DFM); concentrated fluorescent microscopy (CFM); Lowenstein-Jensen (LJ) and Mycobacterial Growth Indicator Tube (MGIT) culture; and Xpert. Overall diagnostic yield and sensitivity were calculated using MGIT as reference comparator. The sensitivity of Xpert in an add-on strategy was calculated as the number of smear negative but Xpert positive participants among MGIT positive participants. Results A total of 123 (29.0%) participants were MGIT culture positive for Mycobacterium tuberculosis . The sensitivity (95% confidence interval) was 31.7% (23.6–40.7%) for DZN, 35.0% (26.5–44.0%) for DFM, 43.9% (34.9–53.1%) for CFM, 76.4% (67.9–83.6) for Xpert and 81.3% (73.2–87.7%) for LJ culture. Add-on strategy Xpert showed an incremental sensitivity of 44.7% (35.7–53.9%) when added to DZN, 42.3% (33.4–51.5%) to DFM and 35.0% (26.5–44.0%) to CFM. This translated to an overall sensitivity of 76.4%, 77.3% and 79.0% for add-on strategies based on DZN, DFM and CFM, respectively, compared to 76.4% for Xpert done independently. From replacement to add-on strategy, the number of Xpert cartridges needed was reduced by approximately 10%. Conclusions Among HIV-infected TB suspects, doing smear microscopy prior to Xpert assay in add-on fashion only identifies a few additional TB cases.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom