z-logo
open-access-imgOpen Access
Accuracy of StepWatch™ and ActiGraph Accelerometers for Measuring Steps Taken among Persons with Multiple Sclerosis
Author(s) -
Brian M. Sandroff,
Robert W. Motl,
Lara A. Pilutti,
Yvonne C. Learmonth,
Ipek Ensari,
Deirdre Dlugonski,
Rachel E. Klaren,
Swathi Balantrapu,
Barry J. Riskin
Publication year - 2014
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0093511
Subject(s) - accelerometer , activity monitor , physical medicine and rehabilitation , gait , preferred walking speed , medicine , physical therapy , physical activity , multiple sclerosis , sedentary behavior , computer science , operating system , psychiatry
There has been increased interest in the objective monitoring of free-living walking behavior using accelerometers in clinical research involving persons with multiple sclerosis (MS). The current investigation examined and compared the accuracy of the StepWatch activity monitor and ActiGraph model GT3X+ accelerometer for capturing steps taken during various speeds of prolonged, over-ground ambulation in persons with MS who had mild, moderate, and severe disability. Methods Sixty-three persons with MS underwent a neurological examination for generation of an EDSS score and undertook two trials of walking on the GAITRite electronic walkway. Participants were fitted with accelerometers, and undertook three modified six-minute walk (6MW) tests that were interspersed with 10–15 minutes of rest. The first 6MW was undertaken at a comfortable walking speed (CWS), and the two remaining 6MW tests were undertaken above (faster walking speed; FWS) or below (slower walking speed; SWS) the participant's CWS. The actual number of steps taken was counted through direct observation using hand-tally counters. Results The StepWatch activity monitor (99.8%–99.9%) and ActiGraph model GT3X+ accelerometer (95.6%–97.4%) both demonstrated highly accurate measurement of steps taken under CWS and FWS conditions. The StepWatch had better accuracy (99.0%) than the ActiGraph (95.5%) in the overall sample under the SWS condition, and this was particularly apparent in those with severe disability (StepWatch: 95.7%; ActiGraph: 87.3%). The inaccuracy in measurement for the ActiGraph was associated with alterations of gait (e.g., slower gait velocity, shorter step length, wider base of support). Conclusions This research will help inform the choice of accelerometer to be adopted in clinical trials of MS wherein the monitoring of free-living walking behavior is of particular value.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom