z-logo
open-access-imgOpen Access
Time-Efficient Myocardial Contrast Partition Coefficient Measurement from Early Enhancement with Magnetic Resonance Imaging
Author(s) -
Shijun Zhang,
Yì Wáng,
Jing Yuan,
Jiyang Jin,
Yuancheng Wang,
Di Chang,
Dehe Weng,
Andreas Greiser,
Shenghong Ju
Publication year - 2014
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0093124
Subject(s) - magnetic resonance imaging , nuclear magnetic resonance , contrast (vision) , contrast enhancement , medicine , physics , radiology , optics
Objective Our purpose was to validate an early enhancement time point for accurately measuring the myocardial contrast partition coefficient (lambda) using dynamic-equilibrium magnetic resonance imaging. Materials and Methods The pre- and post-contrast longitudinal relaxation rates (reciprocal of T1) of the interventricular septum (R1 m ) and blood pool (R1 b ) were obtained from fifteen healthy volunteers and three diabetic patients with hypertension using two optimized T1 mapping sequences (modified Look-Locker inversion recovery) on a 3-Tesla magnetic resonance scanner. Reference lambda values were calculated as the slope of the regression line of R1 m versus R1 b at dynamic equilibrium (multi-point regression method). The simplified pre-/post-enhancement two-acquisition method (two-point method) was used to calculate lambda by relating the change in R1 m and R1 b using different protocols according to the acquisition stage of the post-enhancement data point. The agreement with the referential method was tested by calculating Pearson's correlation coefficient and the intra-class correlation coefficient. Results The lambda values measured by the two-point method increased (from 0.479±0.041 to 0.534±0.043) over time from 6 to 45 minutes after contrast and exhibited good correlation with the reference at each time point (r≥0.875, p<0.05). The intra-class correlation coefficient on absolute agreement with the reference lambda was 0.946, 0.929 and 0.922 at the 6 th , 7 th and 8 th minutes and dropped from 0.878 to 0.403 from the 9 th minute on. Conclusions The time-efficient two-point method at 6–8 minutes after the Gd-DTPA bolus injection exhibited good agreement with the multi-point regression method and can be applied for accurate lambda measurement in normal myocardium.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom