The Morphology of Corneal Cap and Its Relation to Refractive Outcomes in Femtosecond Laser Small Incision Lenticule Extraction (SMILE) with Anterior Segment Optical Coherence Tomography Observation
Author(s) -
Jing Zhao,
Peijun Yao,
Meiyan Li,
Zhi Chen,
Yang Shen,
Zhennan Zhao,
Zimei Zhou,
Xingtao Zhou
Publication year - 2013
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0070208
Subject(s) - meridian (astronomy) , small incision lenticule extraction , optical coherence tomography , femtosecond , ophthalmology , cornea , laser , visual acuity , medicine , materials science , optics , keratomileusis , physics , astronomy
Purpose To investigate the morphology of corneal caps in femtosecond laser small incision lenticule extraction (SMILE) and its relation to the refractive outcomes. Methods A prospective study of fifty-four corneal caps created with VisuMax femtosecond laser were examined using an Fourier-domain optical coherence tomography at 1 day, 1 week, 1 month and 6 months after SMILE. The cap thickness at nine points on each of the four meridians (0°, 45°, 90°, 135°) and the diameter were measured. Cap morphology, changes over time and its correlation with refractive outcomes were assessed. Results The mean achieved central cap thickness were (108.74±5.06) µm at 6 months and (107.32±4.81 ) µm at 1 month postoperatively, significantly thinner than that at 1 day (110.81±7.95) µm and 1 week (109.58±7.48 ) µm ( P< 0.05). The mean diameter on 0° meridian was (7.61±0.07) mm, significantly larger than that on 90° meridian (7.57±0.06) mm ( P = 0.001). Cap morphology showed good regularity, except that the differences of points in two pairs were significant at 1 day postoperatively. The uniformity was consistent over time and the central cap thickness was thinner than those in the paracentral and peripheral areas. The refractive outcomes stabilized within 1 month. Uncorrected distance visual acuity (UDVA) was correlated to the central cap thickness at 1 day and 1 week (both r s = 0.33, p<0.05). The uniformity index was correlated with UDVA ( r s = 0.34, p<0.05) and corrected distance visual acuity ( r s = 0.32, p<0.05) at 1 week postoperatively. Conclusions Corneal caps of SMILE are predictable with good reproducibility, regularity and uniformity. Cap morphology might have a mild effect on refractive outcomes in the early stage. Further study should focus on the impact on the visual quality.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom