Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
Author(s) -
Wei Wang,
Minwen Zhou,
Wenbin Huang,
Xiulan Zhang
Publication year - 2013
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0063591
Subject(s) - trabeculectomy , medicine , tolerability , odds ratio , confidence interval , glaucoma , trab , hazard ratio , intraocular pressure , ophthalmology , surgery , adverse effect , graves' disease , disease
Objective To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. Methods A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measured by weight mean difference (WMD) for the percentage intraocular pressure (IOP) reduction from baseline to end-point, odds ratio (OR) for complete success, and qualified success rates. Tolerability estimates were measured by OR for adverse events. All outcomes were reported with a 95% confidence interval (CI). Data were synthesized by Stata 11.0 SE for Windows. Results Eight controlled clinical trials meeting the predefined criteria were included in the meta-analysis. A total of 605 eyes from 559 patients with medically uncontrolled glaucoma were included. The weighted mean difference of the percentage IOP reduction from baseline was 2.33 (95% confidence interval: −2.59–7.24) when comparing Ex-Press with Trab. Ex-Press was associated with numerically greater, but nonsignificant, IOP lowering efficacy than Trab. The pooled odds ratio comparing Ex-Press with Trab were 0.93 (0.39, 2.23) for the complete success rate and 1.00 (0.39, 2.56) for the qualified success rate. Ex-Press was associated with a significantly lower frequency of hypotony and hyphema than Trab, with pooled ORs of 0.29 (0.13, 0.65) and 0.36 (0.13, 0.97), respectively. Conclusion Ex-Press was associated with equivalent efficacy to Trab in lowering IOP. Comparable proportions of patients reached the IOP target with Ex-Press and Trab. Ex-Press was better tolerated than Trab.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom