Procalcitonin Predicts Real-Time PCR Results in Blood Samples from Patients with Suspected Sepsis
Author(s) -
Antonella Mencacci,
Christian Leli,
Angela Cardaccia,
Marta Meucci,
Amedeo Moretti,
Francesco D’Alò,
Senia Farinelli,
Rita Pagliochini,
Mariella Barcaccia,
Francesco Bistoni
Publication year - 2012
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0053279
Subject(s) - procalcitonin , sepsis , medicine , bacteremia , receiver operating characteristic , confidence interval , gastroenterology , area under the curve , etiology , blood culture , predictive value of tests , biology , microbiology and biotechnology , antibiotics
Background Early diagnosis and rapid bacterial identification are of primary importance for outcome of septic patients. SeptiFast® (SF) real-time PCR assay is of potential utility in the etiological diagnosis of sepsis, but it cannot replace blood culture (BC) for routine use in clinical laboratory. Procalcitonin (PCT) is a marker of sepsis and can predict bacteremia in septic patients. The aim of the present study was to investigate whether PCT serum levels could predict SF results, and could help screening febrile patients in which a SF assay can improve the etiological diagnosis of sepsis. Methods From 1009 febrile patients with suspected sepsis, 1009 samples for BC, SF real-time PCR, and PCT determination were obtained simultaneously, and results were compared and statistically analysed. Receiver operating characteristic (ROC) curves were generated to determine the area under the curve and to identify which cut-off of PCT value produced the best sensitivity to detect SF results. Results Mean PCT values of sera drawn simultaneously with samples SF positive (35.42±61.03 ng/ml) or BC positive (23.14±51.56 ng/ml) for a pathogen were statistically higher than those drawn simultaneously with SF negative (0.84±1.67 ng/ml) or BC negative (2.79±16.64 ng/ml) samples (p<0.0001). For SF, ROC analysis showed an area under the curve of 0.927 (95% confidence interval: 0.899–0.955, p<0.0001). The PCT cut-off value of 0.37 ng/ml showed a negative predictive value of 99%, reducing the number of SF assays of 53.9%, still identifying the 96.4% of the pathogens. Conclusion PCT can be used in febrile patients with suspected sepsis to predict SF positive or negative results. A cut-off value of 0.37 ng/ml can be considered for optimal sensitivity, so that, in the routine laboratory activity, SF assay should not be used for diagnosis of sepsis in an unselected patient population with a PCT value <0.37 ng/ml.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom