Evaluation of a Direct Reverse Transcription Loop-Mediated Isothermal Amplification Method without RNA Extraction for the Detection of Human Enterovirus 71 Subgenotype C4 in Nasopharyngeal Swab Specimens
Author(s) -
Kai Nie,
Shunxiang Qi,
Yong Zhang,
Le Luo,
Yun Xie,
Mengjie Yang,
Yi Zhang,
Li Jin,
Hongwei Shen,
Qi Li,
Xuejun Ma
Publication year - 2012
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0052486
Subject(s) - reverse transcription loop mediated isothermal amplification , loop mediated isothermal amplification , virology , enterovirus 71 , rna extraction , reverse transcriptase , detection limit , enterovirus , biology , outbreak , coxsackievirus , reverse transcription polymerase chain reaction , rna , microbiology and biotechnology , virus , chemistry , gene , dna , chromatography , messenger rna , genetics , biochemistry
Human enterovirus 71 (EV71) is the major causative agent of hand, foot, and mouth disease (HFMD) worldwide and has been associated with neurological complications which resulted in fatalities during recent outbreak in Asia pacific region. A direct reverse transcription loop-mediated isothermal amplification (direct RT-LAMP) assay using heat-treated samples without RNA extraction was developed and evaluated for the detection of EV71 subgenotype C4 in nasopharyngeal swab specimens. The analytical sensitivity and specificity of the direct RT-LAMP assay were examined. The detection limit of the direct RT-LAMP assays was 1.6 of a 50% tissue culture infective dose (TCID 50 ) per reaction and no cross-reaction was observed with control viruses including Cosackievirus A (CVA) viruses (CVA2,4,5,7,9,10,14,16, and 24), Coxsackievirus B (CVB) viruses (CVB1,2,3,4, and 5) or ECHO viruses (ECHO3,6,11, and 19). The direct RT-LAMP assay was evaluated and compared to both RT-LAMP and quantitative real-time PCR (qRT-PCR) in detecting EV71 infection with 145 nasopharyngeal swab specimens. The clinical performance demonstrated the sensitivity and specificity of direct RT-LAMP was reported to be 90.3% and 100% respectively, compared to RT-LAMP, and 86.83% and 100% respectively, compared to qRT-PCR. These data demonstrated that the direct RT-LAMP assay can potentially be developed for the point of care screening of EV71 infection in China.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom